Cooper Instruments & Systems
Worldwide leader for force and pressure instrumentation, sensor systems, and custom calibration services
  • Shop Catalog
    • Load Cells
    • Bridge Amplifiers
    • Digital Instrumentation
    • Torque Load Cells
    • Torque Gages/Screw Drivers
    • Pressure Transducers
    • Pressure Gages
    • Load Force Sensors
    • Electronic Force Gages and Dynamometers
    • Bolt Force Sensors
    • LVDTs
    • Mechanical Test Stands
    • Wire Tension Meters
    • Accessories
    • Wireless Systems
  • Products
    • Test Stands
      • Custom Test Stands
    • OEM Product Line
    • Cooper Distributes For
      • Alliance Sensors
      • Mark-10
      • Straightpoint Wireless
  • Services
    • Calibration Services
      • Premier Calibration
      • Torque Wrench Calibration
    • Process Weighing
    • Custom Solutions
  • Industries
    • Aerospace Industry
    • Automotive Industry
    • Energy Industry
    • Food and Beverage Industry
    • Materials Testing and Handling
    • Medical and Healthcare Industry
    • Client Project Solutions
  • News
    • Videos
  • Contact
    • About
    • Terms
    • Request a Quote
  • 1.800.344.3921
1

LFS 242-.25, LFS 242 Tension/Compression Cell

LFS 242 .25 - Tension/Compression Cell

x 1

$1,250.00 View Cart

Quick Contact
Home / Digital Instruments / Multi-Channel Indicator / DFI 1650-2 – Digital Force Indicator, 2-Channel
“LFS 242 .25 – Tension/Compression Cell” has been added to your cart. View cart
DFI 1650 - Multi-Channel Digital Force Indicator
DFI 1650 - Multi-Channel Digital Force Indicator

DFI 1650-2 – Digital Force Indicator, 2-Channel

Call for Price

SKU: DFI 1650-2 Categories: Digital Instruments, Multi-Channel Indicator, Shop
  • Description

Description

The DFI 1650 is a self-calibrating microprocessor-based transducer indicator with a 6-digit display. It also functions as a signal conditioner when used with transducers equipped with a signal module. Perfect for bench or field operations, this versatile instrument provides an easy-to-read display of data from a variety of different input sensors. Each of the four input channels will accommodate unamplified strain/load sensors, AC/DC displacement transducers, high-level volts/mA transducers, or RTD temperature probes. Older type transducers may be used by purchasing the In- Line module. The unit will instantly self-calibrate the following: zero, span, decimal point and engineering units with any Cooper transducer equipped with the “Sure Cal Signature” option. Manual calibration of the DFI 1650 is done via the front panel menu. An auto-zero circuit will zero the indicator when no load or pressure is applied to the transducer. Standard outputs include RS-232 and 0 – 5 volt analog output. One strain gauge amplifier card comes with the unit. Other different cards are available as options.

  • Automatic calibration
  • User selectable display and filtering options
  • Up to 4 transducer channels
  • AC or DC power
  • 16-bit resolution
  • Up to 800 H z frequency response; field selectable
  • 4 standard programmable limits (open collector outputs)
  • Relay outputs for up to 16 standard/additional limits – optional
  • Different programmable alarm configurations
  • Isolated digital-to-analog voltage or current outputs
  • Multiple load cell summing – optional
  • One strain gauge amplifier card included
  • Input amplifier cards available for four different types of transducers
  • Can be remotely set up from any computer

Specifications

Channels Physical

2

Channels Virtual

1 to 7

Temp. Range Operating

32 to 130 °F

Temp. Range Storage

-20 to 200 °F

Material

Aluminum

Power Required

115, 220 Vac or 12 Vdc Optional

Peak Hold

1 ms

Quad-Limits-Setup

Optional

Quad-Limits-Output

Front panel

Tare Button

Standard

RS232

Standard

RS485

Standard

Software

Optional; firmware programs available

Transducer- Excitation

5 Vdc10 Vdc

Inputs

mV; V; Current

Transducer- Calibration Method

Automatickey pad

Bridge Resistance

350 Ω

Analog Amplifier-Output

D to A type 0-5V; ±5 Vdc; 0-10 Vdc, 4-20 mA Optional

Frequency Response D to A Type

15 Hz

Frequency Response A to A Type

1 kHz

Peak Capture Rate

1 ms

Shunt Calibration

Open collector

Digital- Display

16-Character Alphanumeric Digits

Digital- Display Update

4 per second

Digital Display-Max. Display

999,999

Polar Indications

Yes

Over Range (High)

5 mm

Display Size

Yes

Resolution

16 bit

Digital Display-Type

Vacuum fluorescent

Weight – lbs

4

Mounting

BenchPanelRack

Width

5.6 in

Height

2.8 in

Depth

8.75 in

Option

Bench MountsNEMAPortable Carrying CaseRack Mounts

Input Amplifier Cards

(B) High level volts/mA card(C) RTD millivolts card(D) AC/AC displacement transducerTypes Available: (A) Strain gauge millivolt card

Amplifier Card

One strain gauge card included

Output Voltage Range

5 VDC, ± 5VDC; 10 VDC, =/- 10 VDC

Output Current Range (Optional)

4 to 20 mA

Source

Any channel

Isolation

500 V

Output Resolution

13 bit

Frequency Response

Same as input

Accessory Items1

AC/SOT, Assembly and Calibration of Transducer to Instrumentation ($185.00)

  • 1 Multi-Channel instruments will require an additional calibration fee.

Related products

  • LFS 242-.25, LFS 242 Tension/Compression Cell

    LFS 242 10 – Tension/Compression Cell

    $1,150.00
    Add to cart
  • LFS 210-5K, LFS 210 S Beam Load Cell

    LFS 210 5K – S Beam Load Cell

    $595.00
    Add to cart
  • LFS 210-2K, LFS 210 S Beam Load Cell

    LFS 210 2K – S Beam Load Cell

    $395.00
    Add to cart
Cooper Instruments & Systems
  • Home
  • Shop Catalog
  • About
  • Contact Us
  • Request a Quote
  • News
© Cooper Instruments & Systems 2025
P.O. Box 3048, Warrenton, VA 20188 USA Toll Free: 1-800-344-3921. • Fax: 540-347-4755 • All Rights Reserved.