The DFI 1650 is a self-calibrating microprocessor-based transducer indicator with a 6-digit display. It also functions as a signal conditioner when used with transducers equipped with a signal module. Perfect for bench or field operations, this versatile instrument provides an easy-to-read display of data from a variety of different input sensors. Each of the four input channels will accommodate unamplified strain/load sensors, AC/DC displacement transducers, high-level volts/mA transducers, or RTD temperature probes. Older type transducers may be used by purchasing the In- Line module. The unit will instantly self-calibrate the following: zero, span, decimal point and engineering units with any Cooper transducer equipped with the “Sure Cal Signature” option. Manual calibration of the DFI 1650 is done via the front panel menu. An auto-zero circuit will zero the indicator when no load or pressure is applied to the transducer. Standard outputs include RS-232 and 0 – 5 volt analog output. One strain gauge amplifier card comes with the unit. Other different cards are available as options.
Automatic calibration
User selectable display and filtering options
Up to 4 transducer channels
AC or DC power
16-bit resolution
Up to 800 H z frequency response; field selectable
4 standard programmable limits (open collector outputs)
Relay outputs for up to 16 standard/additional limits – optional
Different programmable alarm configurations
Isolated digital-to-analog voltage or current outputs
Multiple load cell summing – optional
One strain gauge amplifier card included
Input amplifier cards available for four different types of transducers
Can be remotely set up from any computer
Specifications
Channels Physical
4
Channels Virtual
1 to 7
Temp. Range Operating
32 to 130 °F
Temp. Range Storage
-20 to 200 °F
Material
Aluminum
Power Required
115, 220 Vac or 12 Vdc Optional
Peak Hold
1 ms
Quad-Limits-Setup
Optional
Quad-Limits-Output
Front panel
Tare Button
Standard
RS232
Standard
RS485
Standard
Software
Optional; firmware programs available
Transducer- Excitation
5 Vdc10 Vdc
Inputs
mV; V; Current
Transducer- Calibration Method
Automatickey pad
Bridge Resistance
350 Ω
Analog Amplifier-Output
D to A type 0-5V; ±5 Vdc; 0-10 Vdc, 4-20 mA Optional
DFI 1650-4 – Digital Force Indicator, 4-Channel
Call for Price
Description
The DFI 1650 is a self-calibrating microprocessor-based transducer indicator with a 6-digit display. It also functions as a signal conditioner when used with transducers equipped with a signal module. Perfect for bench or field operations, this versatile instrument provides an easy-to-read display of data from a variety of different input sensors. Each of the four input channels will accommodate unamplified strain/load sensors, AC/DC displacement transducers, high-level volts/mA transducers, or RTD temperature probes. Older type transducers may be used by purchasing the In- Line module. The unit will instantly self-calibrate the following: zero, span, decimal point and engineering units with any Cooper transducer equipped with the “Sure Cal Signature” option. Manual calibration of the DFI 1650 is done via the front panel menu. An auto-zero circuit will zero the indicator when no load or pressure is applied to the transducer. Standard outputs include RS-232 and 0 – 5 volt analog output. One strain gauge amplifier card comes with the unit. Other different cards are available as options.
Specifications
Channels Physical
4
Channels Virtual
1 to 7
Temp. Range Operating
32 to 130 °F
Temp. Range Storage
-20 to 200 °F
Material
Aluminum
Power Required
115, 220 Vac or 12 Vdc Optional
Peak Hold
1 ms
Quad-Limits-Setup
Optional
Quad-Limits-Output
Front panel
Tare Button
Standard
RS232
Standard
RS485
Standard
Software
Optional; firmware programs available
Transducer- Excitation
5 Vdc10 Vdc
Inputs
mV; V; Current
Transducer- Calibration Method
Automatickey pad
Bridge Resistance
350 Ω
Analog Amplifier-Output
D to A type 0-5V; ±5 Vdc; 0-10 Vdc, 4-20 mA Optional
Frequency Response D to A Type
15 Hz
Frequency Response A to A Type
1 kHz
Peak Capture Rate
1 ms
Shunt Calibration
Open collector
Digital- Display
16-Character Alphanumeric Digits
Digital- Display Update
4 per second
Digital Display-Max. Display
999,999
Polar Indications
Yes
Over Range (High)
5 mm
Display Size
Yes
Resolution
16 bit
Digital Display-Type
Vacuum fluorescent
Weight – lbs
4
Mounting
BenchPanelRack
Width
5.6 in
Height
2.8 in
Depth
8.75 in
Option
Bench MountsNEMAPortable Carrying CaseRack Mounts
Input Amplifier Cards
(B) High level volts/mA card(C) RTD millivolts card(D) AC/AC displacement transducerTypes Available: (A) Strain gauge millivolt card
Amplifier Card
One strain gauge card included
Output Voltage Range
5 VDC, ± 5VDC; 10 VDC, =/- 10 VDC
Output Current Range (Optional)
4 to 20 mA
Source
Any channel
Isolation
500 V
Output Resolution
13 bit
Frequency Response
Same as input
Accessory Items1
AC/SOT, Assembly and Calibration of Transducer to Instrumentation ($185.00)
Related products
LFS 210 2K – S Beam Load Cell
$395.00 Add to cartLFS 210 50 – S Beam Load Cell
$395.00 Add to cartLFS 210 300 – S Beam Load Cell
$395.00 Add to cart