What is a force? According to Newton's law a force is defined as a mass undergoing an acceleration. It is most common in load cell applications to refer to the force as, you generated it, load. This load can have a multitude of units such as pounds, kilograms, tons, Newtons, etc. In the case of the load being in kilograms, the load has been applied to a load cell using a weight set having "x" number of kilogram masses. Gravity (the "a" in F=ma) supplies the acceleration needed to provide a force to the load cell utilizing kilogram masses. Thankfully, gravity is relatively constant here on the earth and for the most part, kilogram masses and Newton loads can usually be interchanged in order to calibrate load cells or force measuring devices even though a kilogram is technically a unit of mass and a Newton is technically a unit of force.
So what, you may ask, does this have to do with load cells? Well, that all depends upon your application of a load cell. It also ties into what we've already discussed regarding the definition of force or a load. It is that "a" term or acceleration that dictates the accuracy of one's load cell data, with respect to the callibration data. A load cell is a precise device that is calibrated precisely, depending ofcourse on the callibration methodology and quality control. Load cells are callibrated utilizing either a set of known loads being in the form of precise masses or an alternative load application such as through hydraulic means utilizing a precisely callibrated standard load cell.
While force has a value or magnitude, it has another component called a vector or direction. When you use a level, you can see the effects of the direction of gravity. When you use a load cell (believe it or not) you also can see the effects of the direction of gravity. How so? Well if you are measuring pig snouts utilizing a load cell, change the angle of the load cell and re-measure your pig snouts. You'll notice that the load changes. We know that the pig snouts did not change in mass, but we do know that the loads direction changed, thereby impacting the loads magnitude or value.
Okay, so what does this have to do with the quality of the measurement? Frankly, everything. The quality of a measurement is judged based upon the precision of the measurement (the ability to repeat the measurement) and the accuracy of the measurement (how close the measurement's value is to the actual value). As was previously mentioned, the load cell is precisely calibrated and it is calibrated in a universal fashion. That is the objective of the callibration to provide an ideal output based upon ideal loading conditions so that a universal standard may apply. In other words, load cells are callibrated such that if they are callibrated in Warrenton, Virginia, they can be callibrated to achieve the same results in Sydney, Australia (within manufacturer's specification that is).
However, the way in which the load may have been applied in Warrenton, Virginia will most likely not be the same as it is applied in the shop in Sidney, Australia. This reason for the this deviation comes down to setup error.
Again, the quality of the callibration of load cells should be very high from the standpoint of precision or repeatability and accuracy or the proximity of the measurements to the actual true value. This is also why there are criteria for the use of load cells such as mounting and loading interface geometry. This is why load cells are designed to reject certain types of loading geometrical errors such as off axis or tilt. But the question will always arise as to how much error does one induce into the measurement by a typical application where fixturing is employed or the "perfect" axial loading of the device may be altered through the application? Another question that may arise is whether or not the way in which the load cell is used has altered its original calibrated output or has the calibrated output drifted over time? How about this dreaded question? "I dropped my load cell and don't know if it is still reading correctly".
Time and money. That's what it takes to answer those questions. How much of each depends on what methods a company may have at their disposal. Hands down, the best means by which to calibrate a load cell is to use a universal testing machine. That requires lots of money to bring the capability in house. The other problem is keeping up with the quality standards associated with getting your standard calibrated and also the training of employees to run the system. Another option would be to send the load cell itself and/or the entire setup to an outside calibration facility. This typically takes a lot of time, which of course can add up to a lot of money if an entire process is down.
So how can one satify the quality requirements while reducing the time and money burden? Cooper Instruments has developed a test system that is extremely economical for use in testing compression-based systems. The standard system does not utilize a secondary load cell standard, yet easily approaches load cell level uncertainties. The following graph shows the data for 25000 lb test. Three sets of data taken at 1000 lb increments were taken. The standard deviation was calculated to be 18.65 lbs. From ASTM E74, the uncertainty is calulated as the standard deviation multiplied by 2.4. This gives us an uncertainty of 45 lbs, which gives a repeatability of 0.18%.

This uncertainty is achieved without an expensive load cell system that would itself need to be sent out for calibration each year, depending on the quality requirements of the company. This uncertainty allows this system to be utilized as a quck check system in harsh enviroments without the concern of damaging critical and expensive components. The Force Calibration/Check Machine (FCM) has been developed to provide adjustability to accomodate a company's load cell application/setup conditions in order to verify any offset that may be caused by that setup. A CAD model of the system is shown below.

The FCM was developed to complement a company's quality system and help to reduce the time and money associated with the implementation and maintenance of load cells in the company's process. The FCM allows for the quick checks associated with fixturing that may cause offsets in the load cells measurements. While it is recommended that load cells are calibrated once per year, the FCM allows a company's quality standard to implement a system by which the load cells are checked utilizing a relatively low uncertainty. Because it is a low cost system, callibration costs assoicited with maintaining equipment become affordable.
Best of all, it helps to potentially save both time and money if you've dropped your load cell and don't know if it's still reading right. Best of all that is, if you were the one to drop that expensive load cell.
We invite you to contact us with your test stand needs. Mike can be reached at eng@cooperinstruments.com.
We are proud to announce that we have launched our new website and would appreciate any feeback from our customers. Look for us soon on Facebook, LinkedIn, and Twitter.
_________________________________________________________________________________________________
With each new issue of our newsletter, we will select and share a short description of your project with our readers. We want to hear from our customers. Selected product applications will be shared in our upcoming newsletters so we can all learn from your application of our products. Have a story to tell? We are listening. Submit articles to marynorthcooper@gmail.com.
|